Project Notes

Mixer Configuration

mm
elements
mm
mm

Physical Constants

°C
kg/m³
kg/m³
N/m
cSt
cP

Flowrate

Pressure Drop

Calculation Results

Reynolds Number
16544
-
Flow Regime
Turbulent
-
Line Velocity
2.0000
m/s
Volume Flowrate
0.014865
m³/s
Pipe C.S.A.
0.007433
Pressure Drop (Calculated)
0.1746
bar
Pressure Drop
2.53
psi
Rate of Energy Dissipation (E)
202.8230
W/kg
Energy Consumption
2.1105
kW
Turbulence Characteristic (e/D)
0.021083
m/s
Settling Rate (W)
0.000170
m/s
Concentration Ratio (C1/C2)
0.991951
-
Dispersion Quality Assessment
ACCEPTABLE
Average Water Droplet Size (d)
92.93
microns
About this calculator: Computes water-in-oil dispersion quality per ISO 3171 Annex A using ZTMX static mixer element characteristics. Results include droplet size (Hinze equation), settling rate (Stokes law), concentration ratio, and flow analysis across temperature ranges. Select a crude oil type to auto-populate density, viscosity, and interfacial tension at the specified temperature. For detailed product information, see the ZTMX Static Mixer page.

Zelentech Pte Ltd · ISO 3171 / API Chapter 8 reference calculation · Results are for preliminary sizing only and must be verified by qualified engineers.