Retractable Insertion Probe

The ZT-100TEG I-Series Retractable is designed for water-in-TEG measurement in large-diameter glycol circulation lines where the probe must be installed and removed under full process pressure. The retraction kit allows the sensor to be inserted through a full-bore ball valve without process shutdown.

The retraction mechanism includes a packing gland, guide tube, and locking collar to safely control probe insertion and extraction under pressure. Available for pipelines 6" and larger, up to ANSI Class 300.

ZT-100TEG I-Series Retractable Water in TEG Monitor

Key Features

Hot-Tappable

Install and remove the probe under full process pressure without shutdown, using a full-bore ball valve and retraction kit.

TEG-Optimised

Calibrated for the dielectric properties of triethylene glycol across the full range of water loading.

Retraction Kit

Includes packing gland, guide tube, and locking collar for safe, controlled insertion and extraction under pressure.

Hazardous Area Certified

ATEX and IECEx certification for Zone 1 and Zone 2 installations at gas processing facilities.

Robust Construction

316L stainless steel probe and wetted parts. IP67 rated enclosure for outdoor gas plant environments.

Standard Communication

4-20mA analog output and Modbus RTU digital communication for DCS, SCADA, and PLC integration.

Technical Specifications

Measurement PrincipleCapacitance-based sensing
MediumTriethylene glycol (TEG)
Measurement Range0 – 100% water content
Accuracy±0.5% (application dependent)
Pipeline Size6" and larger
Mounting Flange3" ANSI 150RF / 300RF
Max Pressure ClassANSI 300 (Class 300)
Process Temperature−20°C to +120°C
Wetted Materials316L Stainless Steel, PEEK, Viton
Probe LengthApplication dependent (adjustable)
Isolation ValveFull-bore ball valve (supplied separately or as kit)
Enclosure RatingIP67
Hazardous AreaATEX II 1/2 G Ex d IIB T4, IECEx

Electronics

Principle of OperationHigh Frequency Digital Capacitance
Output Signal4–20mA
Digital CommunicationModbus RTU (RS-485)
Power Supply24VDC (4-wire)
Power Consumption2W Max
Measurement Rate1000 per second
Ambient Temperature–20°C to +60°C
Ingress ProtectionIP66

Applications

Large Glycol Headers

Water-in-TEG monitoring in large-diameter glycol headers where the probe must be removable without process interruption.

Central Processing Facilities

Gas plants with continuous uptime requirements where sensor maintenance cannot require a process shutdown.

Offshore Platforms

Glycol dehydration systems on offshore installations where zero-downtime maintenance is essential.

Retrofit Installations

Adding glycol quality monitoring to existing pipelines without shutting down the dehydration system.

Configure Your ZT-100TEG I-Series Retractable

Specify your pipeline size, process conditions, and insertion depth requirements and we will provide a complete quotation including retraction kit.